Our Datacenter Infrastructure
Tier-III & Tier-IV locations
We are selecting the Best Cities and the Best DataCenters across the world. Our Customers no longer need to invest in bricks, mortar, global staff and network management. And as your needs change, spin up new servers and test market them, consolidate, turn down servers and evolve your infrastructure.
Our Data Center Locations
Tier-III & Tier-IV locations
Data Center in USA
- Columbus, OH – TIER IV
- Cincinnati, OH – TIER III
- Dallas, TX – TIER III
- New York, NY – coming soon
- Atlanta, Georgia – coming soon
Data Center in EU
- Vienna, Austria – TIER II
- Frankfurt, Germany – coming soon
Our Data Center Locations in US
Tier-III & Tier-IV locations
Columbus, OhioSee Data Center Details
Cincinnati, OhioSee Data Center Details
Dallas, TexasSee Data Center Details
New York, NYcoming soon
Atlanta, Georgiacoming soon
-
Tier specification:
- Power uptime rating (past 5 years)
- Carriers in the building
- SSAE16 Certified
- PCI Certified
- 24/7/365 Onsite staffed
- Fully redundant Cooling
- Fully redundant Power
- Industry-leading power density(20+ kw/rack)
- Diverse fiber feeds to the building
- 911 rated facility, exempt from Emergency Power Off (EPO) stations
- total power capacity in megawatts (MW)
- Size:
-
Columbus, Ohio (OH)
- 100%
- 30 +
- 2(N+1)
- 2(N+1)
- 50 MW
- 86,000sqft
View Details -
Cincinnati, Ohio (OH)
- 100%
- 6 +
- –
- N+1
- N+1
- –
- 4 MW
- 20,000sqft
View Details -
Dallas, Texas (TX)
- 100%
- 300 +
- 2N
- 2N
- 12 MW
- 40,000sqft
View Details
PROS
- Built to Miami Dade hurricane standards to withstand 146 MPH winds
- Double roofs, cement barriers hardened facility
- Site Geographic High Point in Columbus Area, no flood plane rating
- On power grid backbone from Cleveland to Cincinnati
- All 88 Ohio counties have fiber that home to the Cologix Columbus facility
- Columbus, Ohio is the Capital of Ohio
- On the East / West Fiber route between New York – Pittsburgh – Columbus – Indianapolis – St Louis – Denver – LA
- On the North / South Fiber route from Chicago – Columbus – Atlanta – Dallas
- 8 acre facility
STATE MAP
Columbus, Ohio(OH)
Head Quarter
- 24 X 7 manned facility
- Highest carrier concentration in Ohio, Carrier Neutral
- 911-rated facility with no Emergency Power Off (no EPO stations)
PROS
- Appica, located in a 177,000-square foot building on 2 floors has 20,000 square feet of Tier III data center space in downtown Cincinnati, Ohio.
- Its downtown location enables great access to the carriers servicing Cincinnati
- Cincinnati is the 28th largest metropolitan area in the USA
- Cincinnati is situated where Ohio meets Indiana and Kentucky and Cincinnati is the dominant city for this region
STATE MAP
Cincinnati, Ohio(OH)
Head Quarter
Network:
- Dedicated to our customers’ hosting needs only.
- One of the top regional network convergence points. The North / South central USA backbone: Chicago – Cincinnati – Atlanta – Dallas meets the local Networks. All carrier connections are 10/40 and even 100 Gig.
- Minimum of 10 Gig waves, diverse rings connecting CPG Cities for Intercity Routing
- Fiber carriers enter at disparate points to guard against failure
Precision Environment
- N+1 redundant HVAC (Heating Ventilation Air Conditioning) system. Redundancy built in to cover any failure.
- Every 90 seconds, all air is circulated and filtered to remove dust and contaminants
- Advanced fire suppression systems
Physical Security
- Keycard protocols, biometric scanning protocols, Individual locking cabinets with all access logged and tracked, and around-the-clock interior and exterior surveillance
- Access limited to authorized data center personnel; no one else can enter the production area without prior clearance and appropriate escort
- Datacenter employees undergoes multiple and thorough background security checks
Conditioned Power
- UPS (Uninterruptible Power Supply) for all servers
- 2N redundant UPS power subsystem, with instantaneous failover if the primary UPS fails
- Redundant Battery System where each battery is continuously monitored
- If an extended utility power outage occurs, our routinely tested, on-site diesel generators can run indefinitely
PROS
Network & Fiber:
- Dedicated to our customer’s hosting needs only.
- One of the Top Network convergence Points in the USA. The North / South central USA backbone: Chicago – Atlanta – Dallas meets the East to West (New York – Dallas – LA) plus the South America connections.
- All the Carrier connections are 10/40 and even 100 Gig.
- Minimum of 10 Gig waves, diverse rings connecting CPG Cities for Intercity Routing
- Fiber carriers enter at disparate points to guard against failure
STATE MAP
Dallas, Texas(TS)
Head Quarter
The Dallas Facility Pros:
- The Dallas Infomart, 1.5 Million square feet of DataCenters on 7 floors. More than 110 technology and telecommunications companies make The Dallas Infomart their home.
- It is estimated that there are over 9,000 fiber pairs of carrier terminations to the DataCenters (and clients) in the Infomart building
- Dallas, Texas is the 4th largest Metropolitan Area in the USA
- Dallas and Houston markets combined (240 miles apart) is the 2nd largest Metropolitan Area in the USA (larger than Metro LA, California or Chicago)
- Dallas, Texas is the 14th largest Metropolitan Area in the World
- Within the neighborhood are 20+ more datacenters (Telx, Databank, Tierpoint, CyrusOne, Internap, 365 Main, Savvis and others)
Precision Environment
- 2N+1 redundant HVAC (Heating Ventilation Air Conditioning) system. Both system run and load share and either can carry the full HVAC load.
- Every 90 seconds, all air is circulated and filtered to remove dust and contaminants
- 4 stage Advanced fire suppression systems
- DataCenters in the Infomart:
- Cologix
- Equinix
- Viawest
- XO
- CoreExchange / ZAYO
- ColoGuys
- SoftLayer (IBM)
Physical Security
- Manned 24 X 7, Keycard protocols, biometric scanning protocols, Anti-Tailgate equipped and around-the-clock interior and exterior surveillance
- Access limited to authorized data center personnel; no one else can enter the production area without prior clearance and appropriate escort
- Every data center employee undergoes multiple and thorough background security checks before hire
Conditioned Power
- UPS (Uninterruptible Power Supply) for all servers
- 2N redundant UPS power subsystem, with instantaneous failover if the primary UPS fails
- Redundant Battery System where each battery is continuously monitored
- If an extended utility power outage occurs, our routinely tested, on-site diesel generators can run indefinitely
Our Data Center Locations in Europe
Tier-III & Tier-IV locations
Vienna, AustriaSee Data Center Details
-
Tier specification:
- Power uptime rating (past 5 years)
- Carriers in the building
- SSAE16 Certified
- PCI Certified
- 24/7/365 Onsite staffed
- Fully redundant Cooling
- Fully redundant Power
- Industry-leading power density(20+ kw/rack)
- Diverse fiber feeds to the building
- 911 rated facility, exempt from Emergency Power Off (EPO) stations
- total power capacity in megawatts (MW)
- Size:
-
Vienna, Austria
- 100%
- 30 +
- 2(N+1)
- 2(N+1)
- 50 MW
- 86,000sqft
View Details -
Frankfurt, DE coming soon
- –
- –
- –
- –
- –
- –
- –
- –
- –
- –
- –
- –
View Details